Kobelco excavator parts specialist since 2007 — Guangzhou, China WhatsApp / WeChat: +86 181 4482 5432 · Tel: +86 20-32036036 · kobelco-parts@foxmail.com
Blog

Boom Float on a Kobelco: How the Grading Function Works and Why It Stops

Boom float lets a Kobelco blade and boom follow the ground while grading. Guangzhou Shenyue Machinery Technology Co., Ltd. explains how the function works, how it fails and which parts restore it.

Blog / Boom Float on a Kobelco: How the Grading Fun…
November 7, 2026 · Shenyue Kobelco Parts Team
Kobelco spare solenoid relief valve YN22V00035F1 from stock
The spare solenoid relief valve YN22V00035F1 from our shelf. Solenoid and relief valves of this family sit behind the float command, which is why identification matters before ordering.

Boom float is the grading function that separates a tidy finish from a churned site. Press the float switch and the boom stops holding: it falls under its own weight and then follows the ground as the machine drives forward, so the bucket or blade trims instead of digging. Back-fill against a wall, level a yard, clean a floor after demolition — operators who do this daily use float dozens of times per shift. Guangzhou Shenyue Machinery Technology Co., Ltd. supplies the valves, filters and switches behind the function, and this guide explains how it works, how it fails and what to check before ordering. The wider control context sits in our guide to work modes and pump flow.

What the function does hydraulically

Under normal commands, the main control valve meters oil to the boom cylinders and the load is held as soon as the lever returns to neutral. Float changes that arrangement deliberately: energising the float solenoid shifts a spool in the valve section so both sides of the boom cylinders connect to tank, and the hold function is bypassed. The boom then follows whatever the ground does. Release the switch and the valve returns to its normal position, holding the boom again. The same idea extends beyond the boom on many machines, because dozer blades and some attachments carry their own float position, commanded through the same valve families, so a machine with several float positions runs several solenoids of the same type. That is one more reason the reference on the valve matters more than the reference on the switch. Because the whole function lives in one solenoid command and one spool movement, a fault is usually electrical or cleanliness-related rather than a major hydraulic failure.

Float is a ground-following mode, not a support mode. Never park a load held by float and never work under a boom in float. The function connects the cylinders to tank on purpose, and a load it can hold in neutral is not held in float.

How it fails in the field

The classic first failure is electrical: press the switch and nothing changes, because the solenoid coil has failed, the connector is corroded or the switch itself no longer conducts. Listen for the click or feel the valve respond before touching anything else. The second pattern is dirtier: float engages but behaves badly, with the boom sinking unevenly, catching, or releasing in steps. That points at a sticking spool or contaminated pilot oil, and it is where our guide to the pilot filter and system cleanliness earns its keep — a clogged pilot inline filter, such as the YN50V00020F1 we stock, starves the small command valves first.

The parts to check and order

Three families cover most float repairs. First the command valve: our stock list carries solenoid valve assemblies YN35V00047F3 and LC35V00004F3 and the spare solenoid relief valve YN22V00035F1, with further variants quoted against the serial. Second the filter side: the pilot inline filter YN50V00020F1 and the pilot filter elements that keep the oil clean enough for these valves. Third the switch and its wiring, which fail quietly on machines worked in dust. Which solenoid reference your machine needs depends on model and generation, and these are commonly quoted items: the nameplate and the parts book for the serial are the authority, not a photo of someone else's valve block.

What you seeMost likely causeFirst check
Float switch does nothingCoil, connector or switchListen for the solenoid click
Float engages unevenlySticking spool or dirty pilot oilPilot filter and oil condition
Float drops out intermittentlyConnector or harness damageWiggle test at the connector
Boom creeps in floatValve seat wearValve section inspection

Ordering and fitting

Send the model, the serial and the number printed on the part being replaced, and say whether the fault is "no float at all" or "float behaves badly", because the two descriptions pull toward different parts. Guangzhou Shenyue Machinery Technology Co., Ltd. marks every item genuine, OEM or aftermarket at quotation and confirms references against the serial before quoting. Buyers can shortlist parts on our part-number search page and send the enquiry through the contact page. Kobelco's machine documentation sits at kobelco.co.jp, and the pump and valve families behind these functions come from manufacturers such as Kawasaki, whose own site is khi.co.jp.

Frequently Asked Questions

What does boom float do on a Kobelco excavator?

It connects both sides of the boom cylinders to tank while the switch is held, so the boom follows the ground under its own weight instead of holding. Guangzhou Shenyue Machinery Technology Co., Ltd. supplies the solenoid valves, filters and switches behind the function.

Why does my float switch work but the boom still holds?

That usually means the command reaches the valve but the spool does not move, pointing at a sticking spool or dirty pilot oil rather than the switch. Check the pilot inline filter such as YN50V00020F1 and the pilot oil condition before replacing the valve section.

Is boom float safe to use under a load?

No. Float is a ground-following mode that deliberately bypasses the hold function, so a load held in neutral is not held in float. Never park a load on float and never work under a boom in float.

Which part numbers apply to my machine?

Solenoid assemblies such as YN35V00047F3 and LC35V00004F3 and the spare solenoid relief valve YN22V00035F1 cover much of the range, but fitment varies by model and generation. Guangzhou Shenyue Machinery Technology Co., Ltd. matches every reference against the machine serial before quoting.

Need the parts this article talks about?

Send your part numbers and a photo of the nameplate — real photos and pricing come back with the quote.

Start an Inquiry